Aim DynamicsAutomation & Monitoring Solutions.
Automation &
Monitoring Solutions.

ASR-04-100A:1V by Aim Dynamics

$498.00
Stock: 0 units
Non-Stock Lead Time: 2 Weeks
Power Supply
SKU: ASR-04-100A:1V

Attributes

Categories Rogowski Coils (Flexible CTs)
Manufacturer/Brand Aim Dynamics
Series ASR
Shape/Style Flexible/Rope Coil
Input Type AC
Input Rating (A) 100
Output 1V
# of Inputs 3
Output Type AC
Current or Voltage Output Voltage
Accuracy Class 1.0
Error (%) 1
Phase Error (°) < 0.5
Inner Width (in) 4.00
Inner Height (in) 4.00
Inner Width (mm) 101.60
Inner Height (mm) 101.60
Coil Length (in) 12.5
Connections Leads
Leads 8 ft 22 AWG twisted pair
Supply Voltage 9-36 Vdc
Operating Temperature -20° to 80°C, -4° to 176°F
Humidity (%) 85
Weight (lbs) 1.80
Weight (kg) 0.820
Safety Approvals cURus
Safety Standards CE
Origin USA, Italy
Non-Stock Lead Time 2 Weeks

Description

Aim Dynamics’ ASR series of 3 Phase Super Rogowski Coils with Integrator transform AC inputs of 50 - 4000 Aac to either a Volt or Amp output (model dependant)

  • Voltage Output Specifications
    • Input: 50 - 4000 Aac
    • Storage Temperature
      • -40 to 110 °C
      • -40 to 230 °F
    • Coil Operating Temperature
      • -30 to 80 °C
      • -22 to 176 °F
    • Integrator Operating Temperature
      • -20 to 105 °C
      • -4 to 221 °F
    • Relative Humidity Rating (UL): 85%
    • Standard Leads: 8 ft (2.4m) 22 AWG twisted pair
    • UL Max Voltage: 600 V on primary conductor Output: 0 to 222 mV, 333 mV, 1V, 2V or 5V (AC)
    • Frequency: 25 - 100 kHz (-3 db)
    • Accuracy ±1%
    • Phase Displacement < 0.5°
    • Power Supply: 9-36 Vdc; sold separately
      ASR Low Voltage Builder
  • Super Rogowski Coil Information
    • Features
      • High output
      • Highly linear
      • Wide dynamic range
      • Cannot be damaged by large overloads
      • Completely shielded
      • Calibrated prior to delivery
      • Measurement uniformity is excellent at any position inside the coil
      • Can be used underground
      • Can be used in wet environments
      • Superior degree of rejection to external magnetic influences
    • Specifications
      • Primary Input Range 500 mA – 50 kA
      • Positioning Error Better than 1% of reading
      • Coil Resistance Between 300 and 2000 Ω
      • Working Voltage
        • 1000 V CAT III
        • 600V CAT IV
        • Pollution Degree 2
      • Withstand Voltage 7400 Vrms / 1 min
      • Material Thermoplastic UL94-V0
      • Coil Thickness 12 mm
      • Operating Frequency 40 to 14 kHz (3dB)
      • Mechanical Clasp Strength 77 N
    • Applications
      • Power monitoring & control systems
      • DC ripple measurement
      • Harmonics and transients monitoring
      • Wide range current monitoring
      • Measuring devices, lab instrumentation
      • Underground/wet applications

Resources