G2UM300VL20 24-240VAC/DC by Tele Haase

$180.33
Stock: 0 units
Non-Stock Lead Time: 1 Week
Power Supply
SKU: G2UM300VL20 24-240VAC/DC

Attributes

Categories Monitoring Relays
Manufacturer/Brand Tele Haase
Series Gamma
Mfr Part No 2390304
Switching Capacity 750VA (3A@250Vac), 1250VA (5A@250Vac)
Measuring Variable Voltage
Measuring Input 30 Vac, 30 Vdc, 60 Vac, 60 Vdc, 300 Vac, 300 Vdc
Tripping Delay 0.1~10s
Start-Up Suppression Time 0~10s
On Delay Not Available
Phase Config 1P2W
Number of Functions 6.00
Functionality Over Current+Latch, Over Voltage, Under Current+Latch, Under Voltage, Window Current+Latch, Window Voltage
Has LED Yes
Contact DPDT, 2CO
Power Type AC, DC
Supply Voltage 24-240 Vdc, 24-240 Vac, 30 Vac, 30 Vdc, 60 Vdc, 60 Vac, 300 Vdc, 300 Vac
Switching Voltage 250 Vac
Max Switching Threshold 10-100% of Input Voltage
Min Switching Threshold 5-95% of Input Voltage
Asymmetry Switching Threshold Not Available
Operating Temperature -25° to 40°C, -13° to 104°F
Safety Approvals cULus, EAC
Safety Standards CE
Depth (in) 4.06
Height (in) 3.54
Width (in) 0.89
Weight (lbs) 0.36
Depth (mm) 103.00
Height (mm) 90.00
Width (mm) 22.50
Weight (kg) 0.100
Origin Austria
Non-Stock Lead Time 1 Week

Description

Tele Haase G2UM series of single-phase voltage monitoring devices measure 24 to 240 Vac/Vdc up to 300A (model dependent) with DPDT/2CO contacts

  • Measuring Circuits
    • 10VL20
      • 60mV AC/DC
      • 150mV AC/DC
      • 10V AC/DC
    • 300VL20
      • 30V AC/DC
      • 60V AC/DC
      • 300V AC/DC
  • Multifunction
    • OVER: Overvoltage monitoring
    • OVER+LATCH: Overvoltage monitoring with fault latch
    • UNDER: Undervoltage monitoring
    • UNDER+LATCH: Undervoltage monitoring with fault latch
    • WIN: Monitoring the window between Min and Max
    • WIN+LATCH: Monitoring the window between Min and Max with fault latch
  • Fault latch
  • Supply voltage 24 to 240 Vac/Vdc
  • Indicators
    • Green LED ON: indication of supply voltage
    • Green LED flashes: indication of start-up suppression time
    • Yellow LED ON/OFF: indication of relay output
    • Red LED ON/OFF: indication of failure of the corresponding threshold
    • Red LED flashes: indication of tripping delay of the corresponding threshold
  • Time ranges
    • Start-up suppression time: 0s ~ 10s
    • Tripping delay: 0.1s ~ 10s