G4BM480V12ADTL20 24-240V AC/DC by Tele Haase
$628.03
Stock: 7 units
Non-Stock Lead Time: 1 week
The standard lead time applies only to units not in stock. If you're concerned about the lead time, call +1 (303) 772-6100 to see if we can ship sooner.
Power Supply
SKU: G4BM480V12ADTL20 24-240V AC/DC
Attributes
Categories | Load Monitors |
---|---|
Mfr Part No | 2394706 |
Manufacturer/Brand | Tele Haase |
Series | Gamma |
Phase Config | 1P2W, 3P3W |
Contact | DPDT, 2CO |
Measuring Variable | True Power |
Measuring Input | 48~277 Vac 3Φ, 48~480 Vac 1Φ, 48~480 Vac 3Φ |
Tripping Delay | 0.1~50s |
Start-Up Suppression Time | 0~100s |
Measuring Range | 2.5kW - 10kW |
Overload Capacity Voltage | 1Φ 550 Vac, 3φ 550 Vac |
Width (mm) | 45.00 |
Safety | CE, cULus, EAC |
Functionality | 2MAX, 2MAX+I=0 ON, 2MIN, 2MIN+I=0 ON, MAX/MIN, MAX/MIN+I=0 ON, OVER, OVER+I=0 ON, UNDER, UNDER+I=0 ON, WIN, WIN+I=0 ON |
Measuring Input Current | 0.15 - 6A, 0.3 - 12A |
Overload Capacity Current | 12A permanent |
Switching Capacity | 750VA (3A@250Vac) |
Supply Voltage | 24~240 Vdc, 24~240 Vac |
Weight (lbs) | 0.73 |
Origin | Austria |
Non-Stock Lead Time | 1 week |
Description
The TELE G4BM480V12ADTL20 24-240V AC/DC provides True power monitoring for 1- or 3-phase loads with adjustable switching thresholds, adjustable start-up suppression time, separately adjustable tripping delay, selectable fault latch and temperature monitoring of the motor winding
- Digital setting
- Multifunction
- Temperature monitoring of the motor winding
- Fault latch
- Recognition of disconnected load
- Suitable for VFI (10 to 100Hz)
- Supply voltage selectable via power modules
- DPDT / 2 change over contacts
- Width 45mm
- Industrial design
- Functions
- OVER : Overload monitoring
- OVER+I=0 : ON Overlaod monitoring and recognition of disconnected load (relay ON or OFF)
- UNDER : Underload monitoring
- UNDER+I=0 : ON Underlaod monitoring and recognition of disconnected load (relay ON or OFF)
- 2MIN : Minimum monitoring
- 2MIN+I=0 : ON Minimum monitoring and recognition of disconnected load (relay ON or OFF)
- 2MAX : Maximum monitoring
- 2MAX+I=0 : ON Maximum monitoring and recognition of disconnected load (relay ON or OFF)
- WIN : Monitoring the window between MIN and MAX
- WIN+I=0 : ON Monitoring the window between MIN and MAX and recognition of disconnected load (relay ON or OFF)
- MAX/MIN : Maximum- and minimum monitoring
- MAX/MIN+I=0 : ON Maximum- and minimum monitoring and recognition of disconnected load (relay ON or OFF)