Aim DynamicsAutomation & Monitoring Solutions.
Automation &
Monitoring Solutions.

G4BM480V12ADTL20 24-240V AC/DC by Tele Haase

$628.03
Stock: 7 units
Non-Stock Lead Time: 1 week
Power Supply
SKU: G4BM480V12ADTL20 24-240V AC/DC

Attributes

Categories Load Monitors
Mfr Part No 2394706
Manufacturer/Brand Tele Haase
Series Gamma
Phase Config 1P2W, 3P3W
Contact DPDT, 2CO
Measuring Variable True Power
Measuring Input 48~277 Vac 3Φ, 48~480 Vac 1Φ, 48~480 Vac 3Φ
Tripping Delay 0.1~50s
Start-Up Suppression Time 0~100s
Measuring Range 2.5kW - 10kW
Overload Capacity Voltage 1Φ 550 Vac, 3φ 550 Vac
Width (mm) 45.00
Safety CE, cULus, EAC
Functionality 2MAX, 2MAX+I=0 ON, 2MIN, 2MIN+I=0 ON, MAX/MIN, MAX/MIN+I=0 ON, OVER, OVER+I=0 ON, UNDER, UNDER+I=0 ON, WIN, WIN+I=0 ON
Measuring Input Current 0.15 - 6A, 0.3 - 12A
Overload Capacity Current 12A permanent
Switching Capacity 750VA (3A@250Vac)
Supply Voltage 24~240 Vdc, 24~240 Vac
Weight (lbs) 0.73
Origin Austria
Non-Stock Lead Time 1 week

Description

The TELE G4BM480V12ADTL20 24-240V AC/DC provides True power monitoring for 1- or 3-phase loads with adjustable switching thresholds, adjustable start-up suppression time, separately adjustable tripping delay, selectable fault latch and temperature monitoring of the motor winding

  • Digital setting
  • Multifunction
  • Temperature monitoring of the motor winding
  • Fault latch
  • Recognition of disconnected load
  • Suitable for VFI (10 to 100Hz)
  • Supply voltage selectable via power modules
  • DPDT / 2 change over contacts
  • Width 45mm
  • Industrial design
  • Functions
      OVER : Overload monitoring
    • OVER+I=0 : ON Overlaod monitoring and recognition of disconnected load (relay ON or OFF)
    • UNDER : Underload monitoring
    • UNDER+I=0 : ON Underlaod monitoring and recognition of disconnected load (relay ON or OFF)
    • 2MIN : Minimum monitoring
    • 2MIN+I=0 : ON Minimum monitoring and recognition of disconnected load (relay ON or OFF)
    • 2MAX : Maximum monitoring
    • 2MAX+I=0 : ON Maximum monitoring and recognition of disconnected load (relay ON or OFF)
    • WIN : Monitoring the window between MIN and MAX
    • WIN+I=0 : ON Monitoring the window between MIN and MAX and recognition of disconnected load (relay ON or OFF)
    • MAX/MIN : Maximum- and minimum monitoring
    • MAX/MIN+I=0 : ON Maximum- and minimum monitoring and recognition of disconnected load (relay ON or OFF)