Attribute name | Attribute value |
---|
Functionality | Softstart |
Supply Voltage | 100~240 Vac, 24 Vac, 24 Vdc |
Input Rating (V) | 208~600 Vac |
Input Rating (A) | 6, 12, 18, 25, 30, 38, 45 |
Contact | 2NO |
Phase | 3P3W |
Display | LED |
Series | ADX |
Description
General characteristics
ADXN... is a soft starter with two phase control for the gradual control of the start and stop of asynchronous motors
- Its main strengths are the simplicity of configuration, thanks to a short set of parameters which allows the programming simple and fast, and the compactness, thanks to the enclosure only 45mm wide which makes it suitable for the installation in panels with limited spaces
- It can be used for several applications such as the control of pumps, fans, compressors, conveyor belts and mixers
- It is available with rated current from 6 to 45A, suitable for the installation in systems with rated line voltage from 208 to 600VAC 50/60Hz
- The series consists of 3 versions which differs in the type of programming mode (settings with potentiometers on front or via smartphone with NFC technology and App) and integrated functions
- Every version is available in double variant with auxiliary supply voltage 24VAC/DC or 100...240VAC to suit every need based on the voltage present in the plant
BASIC VERSION ADXNB
The soft starter ADXNB is the ideal solution for those who need a soft starter with basic functions and extremely simple to configure
- The configuration requires the settings of only 3 parameters adjusted with potentiometers present on the front
of the soft starter - The general characteristics are the following
- Built-in bypass relay
- Programming with potentiometers on front: starting voltage, acceleration ramp and deceleration ramp
- Voltage ramp startup
- Free wheel or controlled stop
- Integrated overtemperature protection
- 2 built-in relay outputs with normally open NO contact, with function line contactor control (Run) and TOR (Top Of Ramp)
- Suitable for the control of pumps, fans, blowers, conveyor belts, compressors and general purpose applications
Sku | Supply Voltage | Rated starter current |
ADXNB006 | 100~240VAC | 6 |
ADXNB00624 | 24VAC/DC | 6 |
ADXNB012 | 100~240VAC | 12 |
ADXNB01224 | 24VAC/DC | 12 |
ADXNB018 | 100~240VAC | 18 |
ADXNB01824 | 24VAC/DC | 18 |
ADXNB025 | 100~240VAC | 25 |
ADXNB02524 | 24VAC/DC | 25 |
ADXNB030 | 100~240VAC | 30 |
ADXNB03024 | 24VAC/DC | 30 |
ADXNB038 | 100~240VAC | 38 |
ADXNB03824 | 24VAC/DC | 38 |
ADXNB045 | 100~240VAC | 45 |
ADXNB04524 | 24VAC/DC | 45 |