Manufacturer: Socomec
SKU: DIRIS A40
*
$532.16
Availability: 0 in stock
Non-Stock Lead Time: 1-5 Bus. Days
Minimum Order Quantity is 1
Products specifications
Attribute nameAttribute value
Input50~300 Vac L-N, 87~520 Vac L-L
I/O Option3DI, 2DO
Phase1P2W, 2P3W, 3P3W, 3P4W
FunctionalityCurrent, Energy, Voltage, Power
CommunicationEthernet, RS485, Modbus RTU, Modbus TCP/IP, BACnet/IP, PROFIBUS
Mounting OptionDIN rail, Panel
# of Serial Ports1
Accuracy Class0.2, 0.5
DataloggingYes with embedded webserver WEBVIEW-S
# of Inputs7
Supply Voltage110~277 Vac
SeriesDIRIS

Description

DIRIS A-40 Multifunction power meter - panel mounted. Works with RJ12 smart current sensors.

  • Function
    • The DIRIS A-40 is a panel mounted power monitoring device compatible with TE/TR/iTR/TF smart current sensors, suitable for new or existing electrical installations
    • The DIRIS A-40 has 3 native digital inputs and 2 digital outputs for additional versatility and includes RS485 Modbus RTU, Ethernet Modbus TCP and BACnet IP, and Profibus DP communication to report measurements to external management systems
  • Advantages
    • Plug & Play
      • Color-coded RJ12 cables for easy phase identification when wiring current sensors to the DIRIS A-40
      • Automatic detection of current sensor type and rating
      • Using low-voltage mV current sensors, no shorting blocks are needed, they can be disconnected safely under load
    • Smart sensors
      • Three current sensor formats (solid-core TE, split-core TR/iTR and Rogowski coil TF) allow integration of the DIRIS A-40 into new and existing electrical installations
    • Assisted configuration
      • A configuration wizard guides the user in a step by step process to configure the DIRIS A-40 directly from the screen
      • It also detects and corrects configuration errors which cuts the commissioning time in half and always delivers a reliable result
    • Better than revenue grade
      • Compliant with the IEC 61557-12 standard, guaranteeing the quality and accuracy of the Power Meter
      • Class 0.2 for the meter alone
      • Class 0.5 from 2% to 120% of the rated current, for the global measurement chain (with TE/iTR/TF current sensors)
ModelDescriptionPorts
48250500 / 4825 0500RS485 Modbus RTUDIRIS A40 RS485 MODBUS 3I 2O
48250501 / 4825 0501RS485 Modbus RTU + Ethernet Modbus TCP & BACnet IPDIRIS A40 ETHERN MODBUS 3I 2O
48250502 / 4825 0502RS485 Modbus RTU + Profibus DPV1DIRIS A40 PROFIBUS 3I 2O