The LF 210-S, LF 510-S, LF 1010-S, and LF 2010-S Closed Loop ASIC based Hall effect current sensor measures DC, AC pulse currents' of 200, 500, 1000, 2000 ARMS (respectively) nominal with galvanic isolation.
The LF 205-S/SP3 and LF 210-S/SP3 and Closed Loop ASIC based Hall effect current sensor measures DC, AC pulse currents' of 100 ARMS nominal with galvanic isolation.
Summary:
- Compact design
- Panel mounted in various ways
- Aperture: 15.6 mm (205-S/SP3), 15.59 mm (210-S and 210-S/SP3), 30 x 10 mm (510-S), 40 x 13 mm (1010-S), or 60 x 20 mm (2010-S) diameter for the primary conductor crossing
- Excellent high accuracy at the level of Fluxgate technology but at the price of Hall effect
- Overall accuracy over temperature range of 0.2 % (210-S and 210-S/SP3), 0.3 % (2010-S), 0.4 % (LF 1010-S), 0.5 % (205-S/SP3), or 0.6 % (510-S) of Ipn
- Exceptional offset drift of 0.1 % or 0.05 % (For 2010-S) of Ipn
- Fast response time less than 0.5 µs
- -40°C to + 85°C
- External DC Dual supply ± 12 to ± 15V (For 205-S/SP3, 210-S/SP3, and 210-S), or ± 15 to ± 24V (For 510-S, 1010-S, and 2010-S)
Features- Bipolar and insulated current measurement (For all except the 205-S/SP3)
- Current output
- Closed loop (compensated) current transducer
- Panel mounting (For all except the 205-S/SP3)
- Insulating plastic case recognized according to UL 94-V0 (Only for the 205-S/SP3)
Applications- Windmill inverters (For all except the 205-S/SP3)
- Test and measurement (For all except the 205-S/SP3)
- AC variable speed drives and servo motor drives
- Static converters for DC motor drives
- Battery supplied applications
- Uninterruptible power supplies (UPS)
- Switched mode power supplies (SMPS)
- Power supplies for welding applications
Advantages- Excellent accuracy
- Very low offset drift over temperature
- Very good linearity (205-S/SP3)
- Optimized response time (205-S/SP3)
- Wide frequency bandwidth (205-S/SP3)
- No insertion losses (205-S/SP3)
- High immunity to external interference (205-S/SP3)
- Current overload capability (205-S/SP3)
Part No | Input Rating (A) | Width (mm) | Ratio |
LF-205-S/SP3 | 100 | 15 | 1000:1 |
LF-210-S | 200 | 15 | 2000:1 |
LF-210-S/SP3 | 100 | 15 | 1000:1 |
LF-510-S | 500 | 30 | 5000:1 |
LF-1010-S | 1000 | 38 | 5000:1 |