Questions? Contact Us Now +1 (303) 772-6100

Automation &
Monitoring Solutions.

LF-2010-S 2000A 58mm 5000:1 Hall Effect Ratio Based Closed Loop Current Transformer by LEM

Manufacturer: LEM
SKU: LF-2010-S
$239.00
Availability: 8 in stock
Non-Stock Lead Time: 4-6 Weeks
Minimum Order Quantity is 1
Products specifications
Attribute nameAttribute value
Input Rating (A)2000
Ratio5000:1
Shape/StyleSolid-Core
Error %0.2
Supply Voltage±15~24 Vdc
DirectionBi-directional
Input TypeAC, DC
Opening (greatest dim.)2.3 in (58 mm)
SeriesLF

Description

The LF 210-S, LF 510-S, LF 1010-S, and LF 2010-S Closed Loop ASIC based Hall effect current sensor measures DC, AC pulse currents' of 200, 500, 1000, 2000 ARMS (respectively)  nominal with galvanic isolation.

The LF 205-S/SP3 and LF 210-S/SP3  and Closed Loop ASIC based Hall effect current sensor measures DC, AC pulse currents' of 100 ARMS nominal with galvanic isolation.

Summary:

  • Compact design
  • Panel mounted in various ways
  • Aperture: 15.6 mm (205-S/SP3), 15.59 mm (210-S and 210-S/SP3), 30 x 10 mm (510-S), 40 x 13 mm (1010-S), or 60 x 20 mm (2010-S) diameter for the primary conductor crossing
  • Excellent high accuracy at the level of Fluxgate technology but at the price of Hall effect
  • Overall accuracy over temperature range of 0.2 % (210-S and 210-S/SP3), 0.3 % (2010-S), 0.4 % (LF 1010-S), 0.5 % (205-S/SP3), or 0.6 % (510-S) of Ipn
  • Exceptional offset drift of 0.1 % or 0.05 % (For 2010-S) of Ipn
  • Fast response time less than 0.5 µs
  • -40°C to + 85°C
  • External DC Dual supply ± 12 to ± 15V (For 205-S/SP3, 210-S/SP3, and 210-S), or ± 15 to ± 24V (For 510-S, 1010-S, and 2010-S)
Features
  • Bipolar and insulated current measurement (For all except the 205-S/SP3)
  • Current output
  • Closed loop (compensated) current transducer
  • Panel mounting (For all except the 205-S/SP3)
  • Insulating plastic case recognized according to UL 94-V0 (Only for the 205-S/SP3)
Applications
  • Windmill inverters (For all except the 205-S/SP3)
  • Test and measurement (For all except the 205-S/SP3)
  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Battery supplied applications
  • Uninterruptible power supplies (UPS)
  • Switched mode power supplies (SMPS)
  • Power supplies for welding applications
Advantages
  • Excellent accuracy
  • Very low offset drift over temperature
  • Very good linearity (205-S/SP3) 
  • Optimized response time (205-S/SP3) 
  • Wide frequency bandwidth (205-S/SP3) 
  • No insertion losses (205-S/SP3) 
  • High immunity to external interference (205-S/SP3)
  • Current overload capability (205-S/SP3)
Part NoInput Rating (A)Width (mm) Ratio
LF-205-S/SP3100151000:1
LF-210-S200152000:1
LF-210-S/SP3100151000:1
LF-510-S500305000:1
LF-1010-S1000385000:1
LF-2010-S2000585000:1