Products specifications
Attribute name | Attribute value |
---|
Input | 400 Vac L-N, 690 Vac L-L |
CT Input | 80mA, 100mA, 200mA, 333mV, 1A, 5A, Rogowski Coil |
Phase | 1P2W, 1P3W, 2P3W, 3P3W, 3P4W |
Functionality | Current, Energy, Frequency, Power, Voltage |
Communication | BACnet MS/TP, Modbus RTU, RS485 |
Datalogging | Yes |
Supply Voltage | 100~415 Vac, 100~300 Vdc |
# of Inputs | 4 |
Series | AcuRev |
Description
Accuenergy AcuRev Power Meters track Active, Reactive, and Apparent Energy as well as Active, Reactive, and Apparent Power
- They provide a cost-effective power and energy monitoring solution by combining high performance and an easy integration
- Features 4 channel current input including neutral current measurement, Modbus-RTU protocol, pulse output, and revenue grade accuracy
- Includes a built-in LCD display designed to simplify setup and local reading of meter data
- Features
- Active Energy
- Reactive Energy
- Apparent Energy
- Time-of-Use
- Power Demand
- Peak Power Demand
- Predictive Demand
- Current Demand
- Peak Current Demand
- Voltage
- Current
- Neutral Current (Calculated)
- Active Power
- Reactive Power
- Apparent Power
- Power Factor
- Frequency
- Clock
- Running Time
- Energy Pulse Output
- Relay Output (Alarm or Control) (-X1 model)
- RS485 Modbus-RTU
- RS485 BACnet-MSTP
- Wiring Check
- Temperature (Internal)
- SunSpec
- Cross References
- KW350-P1-D-S-RC to AcuRev-1313-RCT-X1
- KW350-P1-D-S-SC to AcuRev-1313-333-X1
Part No | Current Input | I/O |
---|
AcuRev 1314-333-X0 | 333mV | No Additional I/O |
AcuRev 1314-333-X1 | 333mV | 1 Relay Output |
AcuRev 1314-5A-X0 | 5A/1A | No Additional I/O |
AcuRev 1314-5A-X1 | 5A/1A | 1 Relay Output |
AcuRev 1314-mA-X0 | 80ma/100mA/200mA | No Additional I/O |
AcuRev 1314-mA-X1 | 80ma/100mA/200mA | 1 Relay Output |
| AcuRev 1312 | AcuRev 1313 | AcuRev 1314 |
Application | Realtime power and energy monitoring | Realtime, bi-directional power and energy monitoring | Realtime, multi-function monitoring with neutral current measurement & calculated residual current |
Metering | Energy, Time-of-Use, Power Demand, Current Demand, Voltage, Current, Power, Power Factor, Frequency |
Phase Check | ✓ | ✓ | ✓ |
Sun Spec Compliance | ✓ | ✓ | ✓ |
Time-of-Use | ✓ | ✓ | ✓ |
Relay Output (Alarm or Control) | ✓ | ✓ | ✓ |
Bi-Directional (Net Energy) | | ✓ | ✓ |
Neutral Current | Calculated | Calculated | ✓ |
Residual Current | | | Calculated |
Current Sensing Input | Choose from 5A/1A, 80mA/100mA/200mA, 333mV, or RCT (Rogowski) |
Power Supply | 100-415Vac, 50/60Hz, 100-300Vdc |
Accessories
|
Part No | Description |
AXM-IO1 | 6DI, 1 Power Supply for DI, 2RO |
AXM-IO2 | 4DI, 2DO, 2AO |
AXM-IO3 | 4DI, 2RO, 2AI |
AXM-RS485 | Additional RS485 |
AXM-WEB-PUSH | Ethernet Communication Module + 4GB data logging |
AXM-WEB2 | Dual Port Ethernet Communication Module + 8GB data logging + Wi-Fi |
AXM-WEB2-FOLC | Ethernet + Fiber LC Communication Module + 8GB data logging + Wi-Fi |
AXM-PROFI | Profibus-DP |
AXM-DIN | DIN Rail Mounting Accessory |
Cross References:
Eaton
PXM350MA6121
PXM350MA6121-MC
PXM350MA6141
PXM350MA6310
PXM350MA6320
PXM350MA6321
PXM350MA6341
PXM350MA6521
PXM350MA6521-MC
PXM350MA6541
Siemens
7KM21120BA003AA0
7KM22002EA301DA1
7KM22002EA301EA1
7KM22002EA301HA1
7KM22002EA301JA1
7KM31200BA011DA0
7KM31201BA011EA0
7KM31330BA003AA0
7KM32000CA011AA0
7KM32200BA011DA0
7KM3220-0BA01-1DA0
7KM32201BA011EA0
7KM42111BA003AA0
7KM42120BA003AA0