Products specifications
Attribute name | Attribute value |
---|
Input | 600 Vac |
CT Input | 333mV, 40mA |
Phase | 1P2W, 1P3W, 3P3W, 3P4W |
Accuracy Class | 0.5 |
Functionality | Current, Energy, Frequency, Power, Voltage |
Communication | Modbus RTU, RS485 |
Datalogging | No |
Supply Voltage | 6~24 Vdc, 12~24 Vac |
Series | WattNode |
Description
Continental Control Systems, a leader in accurate, reliable, and economical measurement power and energy, has designed a new power meter that is easy to customize for high-volume OEM applications
- The WattNode Power Meter is a bidirectional (production and consumption) networked energy meter offering energy measurement parameters such as energy (kW), power (kWh), voltage, current, demand, kVAR, kVARh, power factor, frequency, etc.
- These electrical measurements are communicated using the Modbus RTU communication protocol over RS-485
- Revenue-grade accuracy is obtainable using the CCS Accu-CT® family of current transformers, (Class 0.6 or Class 0.3 accuracy), otherwise the meter module utilizes any externally mounted or PCB mounted 0.333 Vac current transformers
- Available factory configured for single or three phase application, the meter is externally (instrument) powered from 12 to 24 Vac or 6 to 24 Vdc.
- New Features
- Correction of CT polarity remotely
- Correction of line voltage connection remotely
- PT ratio register for use with potential transformers
- Current transformer disconnect detection
- SunSpec compliant register list
- Standard Features
- Modbus RTU, RS-485; isolated communication
- 100+ Modbus registers
- For use with safe low voltage (0.333 Vac) or 40mA CTs
- Fast power feature for rapid demand response
- Current Measurement: 5 to 6000 amps
- ANSI C12.20 with Class 0.2 current transformers
- External Power Supply: 12 to 24 Vac isolated or 6 to 24 Vdc
- Single or three phase, wye or delta configuration
- UL and cUL Listed, CE, RoHS compliant
- 5 year warranty
- Electrical Measurements
- True RMS Power: watts, per phase and sum
- Reactive Power: VARs, per phase and sum
- Power Factor: Phase, per phase and average
- True RMS Energy: kWh per phase and sum
- Reactive Energy: VAR hours, sum
- Frequency
- RMS voltage per phase and average
- RMS current per phase and average
- Demand and peak demand
- Modbus Communication
- Protocol: Modbus RTU (binary)
- Baud Rates: selectable from 9,600 to 115,200
- Half Duplex: (two-wire plus common)
Cross References:
Siemens
7KM21120BA003AA0
7KM22002EA301DA1
7KM22002EA301EA1
7KM22002EA301HA1
7KM22002EA301JA1
7KM31200BA011DA0
7KM31201BA011EA0
7KM31330BA003AA0
7KM32000CA011AA0
7KM32200BA011DA0
7KM3220-0BA01-1DA0
7KM32201BA011EA0
7KM42111BA003AA0
7KM42120BA003AA0